HPLC electrochemical detection and quantification of monoamines and their metabolites in rat brain tissue samples
| dc.contributor.author | Viljoen, F.P. | |
| dc.contributor.author | Du Preez, J.L. | |
| dc.contributor.author | Wessels, J.C. | |
| dc.contributor.author | Aucamp, M.E. | |
| dc.contributor.researchID | 11775416 - Viljoen, Francois Petrus | |
| dc.contributor.researchID | 10060510 - Du Preez, Jan Lourens | |
| dc.contributor.researchID | 10204040 - Wessels, Johanna Christina | |
| dc.contributor.researchID | 11927860 - Aucamp, Marique Elizabeth | |
| dc.date.accessioned | 2018-10-24T13:44:21Z | |
| dc.date.available | 2018-10-24T13:44:21Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | The monitoring of monoamines and their metabolites in CNS samples can be very valuable in pharmaceutical and biomedical research. A specific high performance liquid chromatography, coupled to a coulometric electrochemical detection method, for the assay of monoamines (dopamine, norepinephrine, epinephrine and serotonin) and their metabolites in rat brain tissue samples was developed. The chromatographic separation was achieved on a C8 reversed phase column with a mobile phase consisting of 0.1 M sodium formate buffer, 5 mM sodium 1-heptanesulfonate, 0.17 mM ethylenediaminetetraacetic acid disodium salt and 5% v/v acetonitrile (pH ±4.0). The detection was achieved through electrochemical detection, with a coulometric cell potential setting of +650 mV. The flow-rate was at 1 ml/min and the total run time was 50 min. The method was validated according to validation guidelines. The method was found to be linear (R2 > 0.99) over the analytical range (5 to 200 ng/ml) for all monoamines and their metabolites. All the other validation parameters were acceptable and within range. The method was applied to three rat brain areas (pre-frontal cortex, hippocampus and striatum), where the monoamines (except for epinephrine) and their metabolites were easily detected | en_US |
| dc.identifier.citation | Viljoen, F.P. et al. 2018. HPLC electrochemical detection and quantification of monoamines and their metabolites in rat brain tissue samples. Die Pharmazie, 73(10):563-569. [https://doi.org/10.1691/ph.2018.8099] | en_US |
| dc.identifier.issn | 0031-7144 | |
| dc.identifier.uri | http://hdl.handle.net/10394/31517 | |
| dc.identifier.uri | https://www.ingentaconnect.com/content/govi/pharmaz/2018/00000073/00000010/art00003 | |
| dc.identifier.uri | https://doi.org/10.1691/ph.2018.8099 | |
| dc.language.iso | en | en_US |
| dc.publisher | Avoxa | en_US |
| dc.title | HPLC electrochemical detection and quantification of monoamines and their metabolites in rat brain tissue samples | en_US |
| dc.type | Article | en_US |
Files
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.61 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
