The relative biological effectiveness (RBE) of a 200–MeV clinical proton beam

dc.contributor.advisorSlabbert, J.P.
dc.contributor.authorSebeela, Timothy Timo
dc.date.accessioned2014-09-19T15:27:44Z
dc.date.available2014-09-19T15:27:44Z
dc.date.issued2003
dc.descriptionThesis (MSc. ARST) North-West University, Mafikeng Campus, 2003en_US
dc.description.abstractCancer therapy with high-energy particles has proved to be beneficial over the last 10 years. Protons are regarded as being more advantageous because of their distinctive physical depth dose distribution that allows dose conformation to the tumor while sparing normal tissue. In this study, the relative biological effectiveness (RBE) values for the 200-MeV clinical proton beam at iThemba LABS were measured at strategic positions along a 5 cm Spread-Out-Bragg-Peak (SOBP). RBE values were evaluated at the initial plateau of the virgin beam (24.2 mm in Perspex), and at the middle part, distal part and distal edge (12.4% max. dose) along the SOBP (depth in Perspex= 161.4, 181.3 and 207.7 mm respectively). Biological systems used were Chinese hamster ovary cells (CHO-Kl) for both cell survival and micronuclei frequencies as well as human T-lymphocytes for micronuclei frequency analysis. (60)^Co y-irradiation served as a reference. Cell survival measurements yielded RBE values of 1.17 at the distal part and 1.62 at the distal edge (12.4 max. dose). For micronuclei analysis, a limiting RBEap+ay value of 1.3 at the distal part was observed. Using T-lymphocytes, RBEap+/ay values calculated were 2.1, 2.7 and 3.2 at the middle part, distal part and distal edge, respectively. These results show an increase in RBE with depth of penetration and are explained by an increase in ionization density at the end of the SOBP. This is influenced by a high fraction of low-energy protons at that position. Protons were found to be most potent per unit dose towards the end as they slow down to a complete stop. It is recommended that an RBE value slightly greater than the current 1.1 be applied in therapy. Also, that the less steep biological effective depth dose curve be taken into account when dose planning.en_US
dc.description.thesistypeMastersen_US
dc.identifier.urihttp://hdl.handle.net/10394/11405
dc.language.isoenen_US
dc.subjectProton beamsen_US
dc.subjectRelative biological effectiveness (Radiobiology)en_US
dc.titleThe relative biological effectiveness (RBE) of a 200–MeV clinical proton beamen
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Sebeela_TT.pdf
Size:
18.85 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description: