The paper report on the cold start of fuel cell with proton exchange membrane
(PEMFC) at - 40 ℃ using a catalytic heating unit integrated directly into the PEMFC bipolar
plates. This technical solution increases the heat transfer efficiency up to 60% due to direct
contact of the membrane-electrode assembly with the heating unit, and ensure a successful cold
start of the fuel cell from - 40 ℃ to an operating temperature of 35 ℃ within 6 minutes at air
flow rate of 150 mL/min. The hydrogen flow rate is 45 cm3
/s, which corresponds to a hydrogen
concentration in the air flow of ca. 1.8 vol.%, which is below the autoignition point and ensures
the safety of the proposed method. Uniform distribution of heat over the bipolar plates surface
prevents dehydration and thermal degradation of the membrane electrode assembly components
and improve the PEMFC performance after cold start.
Sustainable Development Goals
Description
North-West University, Potchefstroom, South Africa
Keywords
Citation
Ivanova, N.A., Baranov, I.E., Kalinnikov, A.A., Mensharapov, R.M., Spasov, D.D., Sinyakov, M.V., Nikolaev, I.I., Ostrovsky, S.V., Grigoriev, S.A. and Fateev, V.N., 2024, March. Cold start of proton exchange membrane fuel cell using build-in catalytic heater. In Journal of Physics: Conference Series (Vol. 2723, No. 1, p. 012004). IOP Publishing.