Monitoring gearbox oil viscosity by means of motor current signal analysis
Loading...
Date
Authors
Van Vuuren, Pieter A.
Xu, Yuandong
Gu, Fengshou
Ball, Andrew D.
Researcher ID
Supervisors
Journal Title
Journal ISSN
Volume Title
Publisher
Univ of Huddersfield
Record Identifier
Abstract
A number of gearbox failures can be attributed to lubricant related problems. One
measure of the condition of gearbox oil is its viscosity. In electrically powered systems,
motor current signal analysis allows online estimation of the viscosity of gearbox oil
without requiring additional sensors. Previous work on this problem entailed monitoring
the power (and change in power) of sidebands of the shaft frequency in the induction
motor current spectrum. Sideband frequencies in the current spectrum can however be
influenced by other potential problems in the electromechanical system ranging from
bearing faults to gearbox teeth damage.
Changes in the lubricant viscosity result in changes in the mechanical and thermal losses
in the system. These small deviations in the mechanical and thermal losses in the system
become visible in the ratio of the electrical energy demanded by the induction motor to
the kinetic energy of the rotating mechanical parts. Speed and load invariance can be
ensured by normalizing the measured energy ratio with lookup table values obtained
when the system attained thermal equilibrium. Speed or load perturbations in the system
give rise to small deviations in the normalized energy ratio curve. The distributions of
these deviations are significantly different (in a statistical sense) for different oil viscosity
values
Sustainable Development Goals
Description
Keywords
Citation
Van Vuuren, P.A. et al. 2017. Monitoring gearbox oil viscosity by means of motor current signal analysis. First World Congress on Condition Monitoring WCCM 2017, 13-16 June, ILEC Conference Centre, London. [http://eprints.hud.ac.uk/32266/]