The accuracy in measurement of blood pressure (AIM‐BP) collaborative: background and rationale

dc.contributor.authorPadwal, Raj
dc.contributor.authorSchutte, Aletta E.
dc.contributor.authorCampbell, Norm R.C.
dc.contributor.authorWeber, Michael A.
dc.contributor.authorLackland, Daniel
dc.contributor.researchID10922180 - Schutte, Aletta Elisabeth
dc.date.accessioned2020-03-04T06:27:51Z
dc.date.available2020-03-04T06:27:51Z
dc.date.issued2019
dc.description.abstractBlood pressure (BP) measurement, a technique first described over a century ago, is an essential component of clinical care and critical for the detection and management of hypertension.1 Accordingly, the ramifications of inaccurate BP measurement, which is a per‐ sistent and pervasive problem worldwide, are profound.2 Assuming a global prevalence of hypertension of 1.4 billion,3 a 5‐mmHg error in BP measurement has been estimated to result in the incorrect classification of hypertension status in at least 84 million individ‐ uals worldwide.4 In addition, incorrect classification has important ramifications for individual patients, whether it leads to misdiagno‐ sis and inappropriate prescribing of antihypertensive drugs, or to lack of recognition of an clinical condition that can cause devastat‐ ing cardiovascular consequences. The continued rise in the global prevalence of hypertension has made work related to optimizing BP measurement even more critical, and notwithstanding similar initia‐ tives that have been conducted or are ongoing, additional efforts to improve BP measurement on a global scale are clearly needed.5en_US
dc.identifier.citationPadwal, R. et al. 2019. The accuracy in measurement of blood pressure (AIM‐BP) collaborative: background and rationale. Journal of clinical hypertension, 21(12):1780-1783. [ https://doi.org/10.1111/jch.13735]en_US
dc.identifier.issn1524-6175
dc.identifier.issn1751-7176 (Online)
dc.identifier.urihttp://hdl.handle.net/10394/34245
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/epdf/10.1111/jch.13735
dc.identifier.urihttps://doi.org/10.1111/jch.13735
dc.language.isoenen_US
dc.publisherWileyen_US
dc.titleThe accuracy in measurement of blood pressure (AIM‐BP) collaborative: background and rationaleen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
The_accuracy.pdf
Size:
267.9 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description: