Analysis of respirable dust exposure data collected at a Zambian copper mine between 2017 and 2022
Loading...
Date
Authors
Researcher ID
Supervisors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Ltd.
Record Identifier
Abstract
Mine workers are occupationally exposed to respirable dust, which can cause
irreversible lung diseases and controlling exposure concentrations to as low as
reasonably practicable is, therefore, essential. To implement exposure reduction
strategies and adequately manage exposure to hazardous chemicals, exposure
needs to be measured and recorded according to a standard exposure management
plan. This study aimed to assess the available respirable dust exposure data
measured between 2017 and 2022 in various work areas and job categories at two
mining shafts and a concentrator plant of a Zambian copper mine. Additionally, the
monitoring program implemented at the mine was assessed for appropriateness.
Descriptive data analysis was used to create an exposure matrix comprising 253
exposure measurements. Approximately 5.6% of the measured concentrations
exceeded the South African time-weighted average occupational exposure limit
(TWA-OEL) of 3 mg/m3
. The geometric means of respirable dust exposure for shaft
A, shaft B and the concentrator plant were 0.44 mg/m3
, 0.44 mg/m3
, and 0.68 mg/
m3
, respectively. The work areas with the highest maximum exposure results were
the tipping area (18.0 mg/m3
) at shaft A, the sump and waste bin (8.05 mg/m3
) at
shaft B and the screening (10.8 mg/m3
), secondary crusher (14.0 mg/m3
), foreign ore
bin (4.43 mg/m3
), and tertiary crusher (5.07 mg/m3
) areas at the concentrator plant.
It was found that the monitoring strategy implemented at the mine was flawed and
did not collect a sufficient number of samples in each area during each year to make
rigorous statistical assessment possible. This study highlights the sampling strategy's
shortcomings and recommends adopting a standardized monitoring strategy,
such as EN689, to improve the respirable dust monitoring program at the mine.
Additionally, this strategy can be implemented across Zambia and, if implemented
correctly, it has the potential to be improve exposure monitoring across the country
as no standard sampling strategy is currently enforced by the Government.
Sustainable Development Goals
Description
1School of Mathematics and Natural Sciences, Copperbelt University, Kitwe, Zambia, 2Occupational
Hygiene and Health Research Initiative, North-West University, Potchefstroom, South Africa
Citation
Sifanu M, Kalebaila KK, Hayumbu P, Nabiwa L and Linde SJL (2024) Analysis of respirable dust exposure data collected at a Zambian copper mine between 2017 and 2022. Front. Public Health 11:1288485. doi: 10.3389/fpubh.2023.1288485