NWU Institutional Repository

A methodology for the performance characterisation of a variable speed CO2 compressor

dc.contributor.advisorVenter, P V Z
dc.contributor.advisorVan Eldik, Martin, Prof
dc.contributor.authorBester, Johannes Petrus
dc.date.accessioned2018-08-02T13:29:31Z
dc.date.available2018-08-02T13:29:31Z
dc.date.issued2018
dc.descriptionMEng (Mechanical Engineering), North-West University, Potchefstroom Campus, 2018en_US
dc.description.abstractHeat pump cycles have a vast range of industrial applications. A refrigerant withdraws heat from a reservoir, transferring it to another fluid. In order to design and sufficiently size these cycles, accurate operating predictions of all the components are crucial. Amongst these components are the compressor. Some analytical formulations exist to predict the working parameters of a single speed compressor. However, in most cases measurements and specifications known only by the manufacturer, or are difficult to obtain, are needed. The addition of variable speed compressors widened the range in which predictions are made. This study defines a numerical methodology that allows empirical derivation of operating equations for a variable speed reciprocating compressor. Operational equations are derived for a reciprocating carbon dioxide multi-hertz compressor at between 40 and 60 Hz after applying the methodology to a specific compressor. Four out of the six operating parameters must be known to calculate the remaining two. These parameters are; Refrigerant mass flow rate Refrigerant compressor outlet pressure Refrigerant compressor inlet temperatures Refrigerant inlet pressure Refrigerant compressor outlet temperatures Compressor operating frequency During the methodology description, the adaptability, versatility and applicability of the methodology is evaluated and discussed. The methodology has internal decisions that can affect the accuracy and complexity of the end result. Due to the amount of data required and time constraints, experimental data with acceptable accuracies were used instead of actual test-bench values. From the comparison table and the accompanying plots it can be observed that the discharge temperature equation tends to predict values that are on average 0.43% above the experimental values. The absolute error average of 0.99% shows a low measure of inaccuracy. The mass flow equation tends to predict 0.06 % on average above the experimental value. The absolute error value of 0.43% is combined with the plain average to state that over a large sample group, the mass flow prediction equation will be the more accurate equation since the tendency of over- and under-predicted value are minimal. As discussed, these accuracies are between the experimental and predicted values. Comparison with the actual test-bench values for mass flow and discharge temperature will contribute a further around 3% and 5% inaccuracy respectivelyen_US
dc.description.thesistypeMastersen_US
dc.identifier.uriorcid.org/0000-0002-1758-2743
dc.identifier.urihttp://hdl.handle.net/10394/30626
dc.language.isoenen_US
dc.publisherNorth-West University (South Africa), Potchefstroom Campusen_US
dc.subjectR-744en_US
dc.subjectCompressor characterisationen_US
dc.subjectHeat pumpen_US
dc.subjectVariable speed controlen_US
dc.subjectVariable speed driveen_US
dc.subjectNumerical characterisationen_US
dc.subjectUniversal methodologyen_US
dc.titleA methodology for the performance characterisation of a variable speed CO2 compressoren_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bester_JP_2018.pdf
Size:
1.62 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections