    The potential for domestic thermal insulation retrofits on the South African Highveld

    Thumbnail
    View/Open
    The_potential_for_domestic.pdf (701.4Kb)
    Date
    2019
    Author
    Matandirotya, Newton R.
    Cilliers, Dirk P.
    Burger, Roelof P.
    Language, Brigitte
    Piketh, Stuart J.
    Metadata
    Show full item record
    Abstract
    The South African Highveld is a portion on the inland plateau characterized by low winter ambient temperatures. Studies done in several climatic regions around the world have found a positive relationship between inadequate housing and low indoor temperatures during the winter season. Prolonged exposure to low indoor temperature is a threat to human physical health. This study characterizes indoor human thermal comfort conditions in typical low-income residential dwellings during the winter season. Mapping indoor human thermal comfort can assist in exploring the potential for domestic thermal insulation retrofits interventions. In-situ temperature measurements were done in 2014, 2016 and 2017 across three Highveld settlements of kwaZamokuhle, kwaDela, and Jouberton. The sample included a mixture of old (pre-1994), post 1994 Reconstruction and Development Programme (RDP) as well as non-RDP structures. Findings were that 88% of sampled dwellings in Jouberton 2016, 86% in Jouberton 2017, 62% in kwaDela and 58% in kwaZamokuhle had daily mean temperatures below the WHO guideline of 18°C. These low indoor temperatures indicate poor insulation in these sampled dwellings. Across all settlements, insulated dwellings had higher daily mean indoor temperatures than non-insulated dwellings. These findings indicate the potential to use thermal insulation retrofits in improving indoor thermal conditions as the majority of dwellings are non-insulated thereby exposing occupants to low indoor temperatures
    URI
    http://hdl.handle.net/10394/34516
    https://hdl.handle.net/10520/EJC-166bc40419
    https://doi.org/10.17159/2410-972X/2019/v29n1a1
    Collections
    • Faculty of Natural and Agricultural Sciences [4855]

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of NWU-IR Communities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis Type

    My Account

    LoginRegister

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV