• Login
    View Item 
    •   NWU-IR Home
    • Research Output
    • Faculty of Health Sciences
    • View Item
    •   NWU-IR Home
    • Research Output
    • Faculty of Health Sciences
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A toxicity profile of the Pheroid® technology in rodents

    Thumbnail
    View/Open
    A_toxicity_profile.pdf (2.532Mb)
    Date
    2019
    Author
    Kleynhans, Janke
    Elgar, Dale
    Zeevaart, Jan Rijn
    Kotzé, Awie
    Grobler, Anne
    Metadata
    Show full item record
    Abstract
    The Pheroid® drug delivery system is now on the threshold of progressing into human clinical trials for various patented pharmaceutical applications and a systematic investigation of its toxicological properties in vitro and in vivo is thus a priority. Colloidal dispersions (nano- and microemulsions) demonstrate the ability to be adapted to accommodate either lipophilic, hydrophilic or amphiphilic drug molecules. The colloidal dispersions investigated during this evaluation has a general size of 200 nm - 2 μm, a zeta-potential of -25 mV and the main ingredient was ethyl esters of essential fatty acids. The Ames mutagenicity assay was performed on selected Salmonella thyphimurium strains TA98, TA100 and TA102. The Ames assay included S9 metabolic activation and no mutagenicity was present during the assay. The effect of acute and subchronic administration on a biological system was investigated in two species of rodent (BALB/c mice and Sprague-Dawley rats). Observations focused on the physical condition, blood biochemical analysis and the haematological profiles. Gross necropsy was performed on all the test animals. Organ weights followed by histopathology of selected organ tissues were recorded. During the acute evaluation animals showed tolerance of the maximum prescribed dose of 2000 mg/kg (according to OECD guidelines) in two rodent species after intravenous administration (absolute bioavaibility). The oral formulation was tolerated without incidents in both acute and subchronic studies. Although valuable baseline safety data was obtained regarding the Pheroid® system, future studies with the entrapped active pharmaceutical ingredients is necessary to provide a definitive safety profile
    URI
    http://hdl.handle.net/10394/33384
    https://www.sciencedirect.com/science/article/pii/S2214750018301835/pdfft?md5=873dd031b7b7b9553b8d82e3da2c86ec&pid=1-s2.0-S2214750018301835-main.pdf
    https://doi.org/10.1016/j.toxrep.2019.08.012
    Collections
    • Faculty of Health Sciences [2404]

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of NWU-IR Communities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis Type

    My Account

    LoginRegister

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV