Show simple item record

dc.contributor.authorViljoen, F.P.
dc.contributor.authorDu Preez, J.L.
dc.contributor.authorWessels, J.C.
dc.contributor.authorAucamp, M.E.
dc.contributor.authorMeyer, L.C.R.
dc.contributor.authorPohlin, F.
dc.date.accessioned2019-05-15T11:22:01Z
dc.date.available2019-05-15T11:22:01Z
dc.date.issued2019
dc.identifier.citationViljoen, F.P. et al. 2019. An HPLC-DAD validated method for the detection and quantification of cortisol, corticosterone and melatonin in plasma samples of two different animal species. Die Pharmazie, 74(4):206-211. [https://doi.org/10.1691/ph.2019.8225]en_US
dc.identifier.issn0031-7144
dc.identifier.urihttp://hdl.handle.net/10394/32345
dc.identifier.urihttps://www.ingentaconnect.com/contentone/govi/pharmaz/2019/00000074/00000004/art00003
dc.identifier.urihttps://doi.org/10.1691/ph.2019.8225
dc.description.abstractThe monitoring of endogenous hormone plasma levels could be valuable in biomedical, veterinary and pharmaceutical research. A specific high performance liquid chromatography method with diode array detection, for the assay of cortisol, corticosterone and melatonin in animal plasma was developed and validated. The chromatographic separation was achieved on a C8 reversed phase column with a mobile phase consisting of HPLC-grade water and 35% v/v acetonitrile (pH ± 3.36). The detection was achieved through diode array detection, with two set wavelengths; 245 and 275 nm. The flow rate was at 1 ml/min and the total run time was 50 min. The method was validated according to validation guidelines (Shabir, 2006; US FDA, 2013). The method was found to be linear (R2 > 0.99) over the analytical range (10 to 500 ng/ml) for all three analytes. All the other validation parameters were acceptable and within range. The method was applied to plasma samples from Sprague-Dawley rats and white rhinocerosen_US
dc.language.isoenen_US
dc.publisherAvoxaen_US
dc.titleAn HPLC-DAD validated method for the detection and quantification of cortisol, corticosterone and melatonin in plasma samples of two different animal speciesen_US
dc.typeArticleen_US
dc.contributor.researchID11775416 - Viljoen, Francois Petrus
dc.contributor.researchID10060510 - Du Preez, Jan Lourens
dc.contributor.researchID10204040 - Wessels, Johanna Christina
dc.contributor.researchID11927860 - Aucamp, Marique Elizabeth


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record