    A calibration neutron monitor: energy response and instrumental temperature sensitivity

    Thumbnail
    Date
    2008
    Author
    Krüger, H.
    Moraal, H.
    Bieber, J.W.
    Clem, J.M.
    Evenson, P.A.
    Metadata
    Show full item record
    Abstract
    Neutron monitors are integral detectors of secondary cosmic rays. Since each of them has its own detection efficiency, energy spectra cannot readily be derived from their observations. To circumvent this problem, latitudinal surveys have been conducted for many years with mobile neutron monitors to derive such spectra. Another way, however, is to use the worldwide stationary neutron monitor network, but then the counting rates of these monitors must be normalized sufficiently accurately against one another. For this reason, two portable calibration neutron monitors were built at the Potchefstroom campus of the North-West University, South Africa. When calibrations of an adequate number of the worldwide neutron monitors have been done, this paper demonstrates that the differential response functions derived from them will provide experimental data for modulation studies in the rigidity range of 1 to 15 GV. Several properties of these calibrators were investigated, in order to achieve sufficient calibration accuracy. The energy response over the cutoff rigidity range from the poles to the equator, as well as the instrumental temperature sensitivity, are described in this paper. The main conclusion is that the calibrator has a difference of almost 4% in its energy response over the cutoff rigidity range 0–16 GV in comparison with a standard 3NM64 neutron monitor. Furthermore, it is shown that not only the calibrator, but also the NM64 and IGY monitors, have fairly large instrumental temperature sensitivities. Correction coefficients for these effects are given
    URI
    http://hdl.handle.net/10394/2612
    http://dx.doi.org/doi:10.1029/2008JA013229
    http://onlinelibrary.wiley.com/doi/10.1029/2008JA013229/abstract
    Collections
    • Faculty of Natural and Agricultural Sciences [4817]

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of NWU-IR Communities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis Type

    My Account

    LoginRegister

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV