Show simple item record

dc.contributor.authorRudolph, Johnny
dc.date.accessioned2014-08-14T07:19:19Z
dc.date.available2014-08-14T07:19:19Z
dc.date.issued2011
dc.identifier.urihttp://hdl.handle.net/10394/11077
dc.descriptionThesis (M.Ing. (Nuclear Engineering))--North-West University, Potchefstroom Campus, 2012en_US
dc.description.abstractThe present power system is loaded with sophisticated energy conversion technologies like solid state converters. With the rapid advance in semiconductor technology, power electronics have provided new devices that are highly efficient and reliable. These devices are inherently non-linear, which causes the current to deviate from sinusoidal conditions. This phenomenon is known as harmonic current distortion. Multiple consumers are connected to the utility at the point of common coupling. Harmonic currents are then transmitted into the distribution system by various solid state users and this could lead to voltage distortion. Harmonic distortion is just one of the power quality fields and is not desirable in a power system. Distortion levels could cause multiple problems in the form of additional heating, increased power losses and even failing of sensitive equipment. Utility companies like Eskom have power quality monitors on various points in their distribution system. Data measurements are taken at a single point of delivery during certain time intervals and stored on a database. Multiple harmonic measurements will not be able to describe distortion patterns of the whole distribution system. Analysis must be done on this information to translate it to useful managerial information. The aim of this project is to develop a benchmarking methodology that could aid the supply industry with useful information to effectively manage harmonic distortion in a distribution system. The methodology will implement distortion indexes set forth by the Electrical Power Research Institute [3], which will describe distortion levels in a qualitative and quantitative way. Harmonic measurements of the past two years will be used to test the methodology. The information is obtained from Eskom’s database and will benchmark the North-West Province distribution network [40]. This proposed methodology will aim to aid institutions like NERSA to establish a reliable power quality management system.en_US
dc.language.isoenen_US
dc.subjectBenchmarking indicesen_US
dc.subjectHarmonicsen_US
dc.subjectVoltage distortionen_US
dc.subjectCurrent distortionen_US
dc.subjectPower qualityen_US
dc.titleA benchmarking model for harmonic distortion in a power systemen
dc.typeThesisen_US
dc.description.thesistypeMastersen_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record