    A conceptual study of a natural circulation cooling loop for a PWR containment

    Thumbnail
    View/Open
    Jacobs_LE.pdf (2.087Mb)
    Date
    2011
    Author
    Jacobs, Louis Egbert.
    Metadata
    Show full item record
    Abstract
    The removal of heat from the containment building is an important consideration in the design of a nuclear power plant. In this investigation a simple rectangular natural circulation loop was simulated to determine whether it could possibly be used to remove usable quantities of heat from a containment building. The loop had a vertical pipe on the inside and outside of the containment building. These pipes acted as heat exchangers. Single phase and two phase cases were simulated by imposing a temperature on the respective vertical leg pipe walls and determining the heat absorption from the containment building. The heat was conveyed from the inside of the building to the outside via the natural circulation phenomenon. A literature study was done to cover topics relevant to this investigation. A theoretical model using conservation equations and control volumes was derived. This model was based largely on knowledge gleaned from the literature study. The theoretical model was a simple homogenous model, which was sufficiently detailed for a conceptual investigation. The theoretical model was then manipulated into a form suitable for use in a computer simulation program. Simplifications were made to the simulation model and underlying theory due to the nature of the investigation. The simulation model was validated against published experimental results. During the simulation phase a number of cases were investigated. These cases were divided into base cases and parametric studies. During the base case simulations the change of key fluid variables along the loop was examined. During the parametric studies the hot and cold leg inside wall temperatures, loop geometry and pipe diameter were varied. The effect of these parameters on the heat absorption from the containment was determined. The simulations showed that with the current assumptions about 75 to 120 of the natural circulation loops are needed depending on their geometry and containment conditions. The heat removal rates that were calculated varied from 50 kW to 600 kW for a single loop. As explained in the final chapter, there are many factors that influence the results obtained. The natural circulation concept was deemed to be able to remove usable quantities of heat from the containment building.
    URI
    http://hdl.handle.net/10394/7608
    Collections
    • Engineering [1424]

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of NWU-IR Communities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis Type

    My Account

    LoginRegister

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV