• Login
    View Item 
    •   NWU-IR Home
    • Electronic Theses and Dissertations (ETDs)
    • Engineering
    • View Item
    •   NWU-IR Home
    • Electronic Theses and Dissertations (ETDs)
    • Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Biomechanical quantification and analysis of the human foot and ankle joint complex

    Thumbnail
    View/Open
    Buys_S.pdf (4.454Mb)
    Date
    2024-04
    Author
    Buys, Shanya
    Metadata
    Show full item record
    Abstract
    The human foot and ankle joint complex are essential lower limb components responsible for facilitating smooth gait and other activities related to everyday living. Unfortunately, this natural movement is lost in amputees and difficult to replicate even with the aid of prosthetic devices. Thus, to contribute to the understanding of the fundamental characteristics relative to natural lower limb movement, this study aims to quantify and analyse the biomechanical features of the human foot and ankle joint complex in relation to the sagittal and frontal planes of the foot. The research design and methodology comprise an experimental process wherein 15 healthy young to middle-aged individuals were recruited. The participants were required to navigate a set of five low-level activities, particularly 1) level walk, 2) step up and down, 3) 20° slope incline and decline walk, 4) standing and sitting, and 5) lifting an object. The participants were equipped with a sensor platform device consisting of three ADXL 345 sensors, strategically positioned to restrict kinematic data to the foot and ankle. Notably, data from the sensors were collected in conjunction with reference data from a motion capture camera system to ensure the integrity of the sensors. In terms of kinetics, force plates were used to obtain the reaction forces acting on participants during the experimental activities. It was observed that a loss of data, which primarily occurred due to poorly optimised code of the interface application, significantly decreased the accuracy of the data collected from the sensor platform. Nonetheless, a comparative analysis of the findings showed similar patterns between the experimental results and the reference data, thus validating the research design and method used. Therefore, suggestions could be made to enhance data accuracy and generalisability in future research. For the kinetic aspect of this study, it was suggested that a modular force plate system be used to investigate the reaction forces of supplementary experimental activities. In terms of the kinematic data, accuracy could be enhanced by recruiting a larger sample size, optimising the code behind the application interface, and considering the transverse plane of the foot in addition to the sagittal and frontal plane.
    URI
    https://orcid.org/0000-0002-3894-7991
    http://hdl.handle.net/10394/42678
    Collections
    • Engineering [1424]

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of NWU-IR Communities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis Type

    My Account

    LoginRegister

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV