Show simple item record

dc.contributor.advisorRens, A.P.J., Prof
dc.contributor.authorDe Jager, F.A.
dc.date.accessioned2018-09-06T08:53:15Z
dc.date.available2018-09-06T08:53:15Z
dc.date.issued2018
dc.identifier.urihttps://orcid.org/0000-0001-8918-7163
dc.identifier.urihttp://hdl.handle.net/10394/30901
dc.descriptionMEng (Electrical and Electronic Engineering), North-West University, Potchefstroom Campusen_US
dc.description.abstractThe research assessed the possibility of using a wide area measurement system that uses synchrophasor data to calculate operational limits of an overhead line. These applications have become achievable to utility companies without the need of expensive phasor measurement units. Phasor measurements can be obtained by applying the IEEE C37-118 standard in general power system measuring equipment. This dissertation presents the use of synchrophasors in the on-line modelling of a transmission line. Using time coherent measurements, the line parameters are continuously derived, which is then also used to monitor line temperature, sag, power transfer and voltage stability. This enables the system operator to base decisions on real field data and less on estimated values as produced by state estimators. The methodology were verified by means of simulation and then validated by field data obtained across a 330 kV, 521 km line. Promising results were obtained and analysis of the results confirmed that comprehensive transmission line performance monitoring is attainable. The electrical characteristic of the line can be made visible by tracking the variation in line parameters, line temperature and also line sag can be estimated. From a stability point of view, further application was shown to be the tracking of power transfer to visualise utilisation of installed line capacity and voltage stability across the line by means of tracking the locus of the operating points on P-V curves.en_US
dc.language.isoenen_US
dc.publisherNorth-West Universityen_US
dc.subjectSynchrophasor applicationsen_US
dc.subjectTransmission line modellingen_US
dc.subjectTransmission line parameter estimationen_US
dc.subjectPower system stabilityen_US
dc.titleOn-line monitoring of a transmission line using synchrophasor measurementsen_US
dc.typeThesisen_US
dc.description.thesistypeMastersen_US
dc.contributor.researchID10200029 - Rens, Abraham Paul Johannes (Supervisor)
dc.contributor.researchID22189556 - De Jager, Francois Alwyn


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record