• Login
    View Item 
    •   NWU-IR Home
    • Research Output
    • Faculty of Engineering
    • View Item
    •   NWU-IR Home
    • Research Output
    • Faculty of Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of harmonic distortion from multiple renewable sources at a distribution substation

    Thumbnail
    Date
    2017
    Author
    Peterson, Brandon
    Rens, Johan
    Botha, Gerhard
    Meyer, Jan
    Desmet, Jan
    Metadata
    Show full item record
    Abstract
    Harmonic emission assessment in a distribution network with existing background voltage harmonics is a challenge for Renewable Power Producers (RPP) aiming to achieve grid code compliance. Dynamic interaction of harmonic sources at a Point of Common Coupling (PCC) renders the general summation law in IEC 61000-3-6 impractical, as harmonic phasors do not conform to the addition of rms values using alpha factors. The dynamic interaction of different PV plants and non-linear traction loads connected to the same 132 kV PCC is analyzed to validate the practical constraints in assessing grid code compliance requirements It is demonstrated that an innovative application of phasor aggregation, albeit scientifically challenged, could present a pragmatic approach for engineers tasked with network Power Quality performance
    URI
    http://hdl.handle.net/10394/26186
    https://ieeexplore.ieee.org/document/8078327/
    https://doi.org/10.1109/AMPS.2017.8078327
    Collections
    • Conference Papers - Potchefstroom Campus [713]
    • Faculty of Engineering [1136]

    Related items

    Showing items related by title, author, creator and subject.

    • Thumbnail

      A practical evaluation of harmonic emission assessment 

      Serfontein, Duan; Rens, Johan (IEEE, 2011)
      This paper reports an evaluation of harmonic emission assessment. The results obtained by the Harmonic Vector Method are correlated to the behavior of harmonic active power by means of synchronized measurements in a ...
    • Thumbnail

      The assessment of waveform distortion in power systems : validation of methods based on single–point measurements 

      Serfontein, Duan (North-West University, 2011)
      The portion of energy converted by non-linear loads in the modern power system is increasing due to the energy-efficiency and sophistication possible with power electronics. Higher voltage and energy ratings are continuously ...
    • Thumbnail

      On harmonic emission assessment: a discriminative approach 

      Peterson, B.B.; Rens, J.; Botha, M.G.; Desmet, J. (SAIEE, 2017)
      An improvement in the assessment of harmonic emissions as contributed by renewable generation such as a Photovoltaic (PV) plant, at a Point of Connection (PoC) to a distribution network, is needed. Both the generating ...

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of NWU-IR Communities & CollectionsBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsAdvisor/SupervisorThesis Type

    My Account

    LoginRegister

    Copyright © North-West University
    Contact Us | Send Feedback
    Theme by 
    Atmire NV