Show simple item record

dc.contributor.authorDe Beer, Frikkie
dc.contributor.authorVan der Merwe, Jan-Hendrik
dc.contributor.authorBessarabov, Dmitri
dc.date.accessioned2017-11-02T12:39:57Z
dc.date.available2017-11-02T12:39:57Z
dc.date.issued2017
dc.identifier.citationDe Beer, F. et al. 2017. PEM water electrolysis: preliminary investigations using neutron radiography. 8th International Topical Meeting on Neutron Radiography, Beijing, China, 4-8 Sep 2016. Physics procedia, 88:19-26. [https://doi.org/10.1016/j.phpro.2017.06.002]en_US
dc.identifier.issn1875-3892
dc.identifier.issn1875-3884 (Online)
dc.identifier.urihttp://hdl.handle.net/10394/26014
dc.identifier.urihttps://doi.org/10.1016/j.phpro.2017.06.002
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1875389217300524
dc.description.abstractThe quasi-dynamic water distribution and performance of a proton exchange membrane (PEM) electrolyzer at both a small fuel cell's anode and cathode was observed and quantitatively measured in the in-plane imaging geometry direction(neutron beam parallel to membrane and with channels parallel to the beam) by applying the neutron radiography principle at the neutron imaging facility (NIF) of NIST, Gaithersburg, USA. The test section had 6 parallel channels with an active area of 5 cm2 and in-situ neutron radiography observation entails the liquid water content along the total length of each of the channels. The acquisition was made with a neutron cMOS-camera system with performance of 10 sec per frame to achieve a relatively good pixel dynamic range and at a pixel resolution of 10 x 10 μm2. A relatively high S/N ratio was achieved in the radiographs to observe in quasi real time the water management as well as quantification of water / gas within the channels. The water management has been observed at increased steps (0.2A/cm2) of current densities until 2V potential has been achieved. These observations were made at 2 different water flow rates, at 3 temperatures for each flow rate and repeated for both the vertical and horizontal electrolyzer orientation geometries. It is observed that there is water crossover from the anode through the membrane to the cathode. A first order quantification (neutron scattering correction not included) shows that the physical vertical and horizontal orientation of the fuel cell as well as the temperature of the system up to 80 °C has no significant influence on the percentage water (∼18%) that crossed over into the cathode. Additionally, a higher water content was observed in the Gas Diffusion Layer at the position of the channels with respect to the landsen_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectElectrolysisen_US
dc.subjectNeutron Radiographen_US
dc.subjectNIST-NCNRen_US
dc.subjectPEM fuel cellen_US
dc.titlePEM water electrolysis: preliminary investigations using neutron radiographyen_US
dc.typePresentationen_US
dc.contributor.researchID22730389 - Bessarabov, Dmitri Georgievich
dc.contributor.researchID20507437 - Van der Merwe, Jan Hendrik Petrus


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record