Show simple item record

dc.contributor.authorPeach, Retha
dc.contributor.authorKrieg, Henning M.
dc.contributor.authorKrüger, Andries J.
dc.contributor.authorRossouw, Jacobus J.C.
dc.contributor.authorBessarabov, Dmitri
dc.contributor.authorKerres, Jochen
dc.date.accessioned2016-09-26T11:23:15Z
dc.date.available2016-09-26T11:23:15Z
dc.date.issued2016
dc.identifier.citationPeach, R. et al. 2016. Novel cross-linked partially fluorinated and non-fluorinated polyaromatic PBI-containing blend membranes for SO2 electrolysis. International journal of hydrogen energy, 41:11868-11883. [https://doi.org/10.1016/j.ijhydene.2016.05.246]en_US
dc.identifier.issn0360-3199
dc.identifier.urihttp://hdl.handle.net/10394/18876
dc.identifier.urihttps://doi.org/10.1016/j.ijhydene.2016.05.246
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0360319915308879
dc.description.abstractVarious partially fluorinated and non-fluorinated polyaromatic and PBI blend components were covalent-ionically cross-linked to obtain proton exchange membranes that can be applied in an SO2 electrolyser. During SO2 electrolysis, SO2 and H2O are converted to H2 and H2SO4, which implies that the membranes to be used for this process should have both a high proton conductivity and H2SO4 stability. The acid stability of the blend membranes were evaluated in an 80 wt% H2SO4 environment for 120 h at 80 and 95 °C respectively. From the characterization results obtained by monitoring weight and thickness change, IEC, SEM-EDX and TGA signal's before and after treatment, it was determined that the novel cross-linked blend membranes, containing only partially fluorinated polymer components, showed exceptional stability. The cross-linked partially fluorinated polyaromatic PBI blended membrane (SFS001-F6PBI-BrPAE) and Nafion® 115 were selected for electrochemical evaluation by obtaining polarization curves at 80 and 95 °C. The SFS001-F6PBI-BrPAE performed the best at operation temperature of 95 °C reaching a current density of 0.63 A cm−2 in comparison to the 0.42 A cm−2 obtained for Nafion® 115 at 1.0 V. Durability of the membranes within the electrolyser were measured by means of voltage stepping and subsequent characterization using SEM-EDX, TEM and TGA which confirmed the minimal degradation observed for the 250 cycles completeden_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectPBI blendeden_US
dc.subjectH2SO4 stabilityen_US
dc.subjectSO2 electrolysisen_US
dc.subjectPartially fluorinated blend componentsen_US
dc.subjectVoltage steppingen_US
dc.titleNovel cross-linked partially fluorinated and non-fluorinated polyaromatic PBI-containing blend membranes for SO2 electrolysisen_US
dc.typeArticleen_US
dc.contributor.researchID11087137 - Krieg, Henning Manfred
dc.contributor.researchID21640904 - Peach, Retha
dc.contributor.researchID24775290 - Kerres, Jochen A.
dc.contributor.researchID13061631 - Krüger, Andries Johannes
dc.contributor.researchID22730389 - Bessarabov, Dmitri Georgievich
dc.contributor.researchID22114688 - Rossouw, Jacobus Johannes Cloete


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record