    Study on energy losses in industrial sector caused by low actual efficiency of induction motors

    Thumbnail
    Date
    2014
    Author
    Dobzhanskyi, O.
    Gouws, R.
    Metadata
    Show full item record
    Abstract
    This paper presents a study on energy losses in the industrial sector caused by low actual efficiency of induction motors (IMs). The main reasons are discussed and an efficiency analysis of a 3-phase induction motor, commonly used in industry, presented to compare such motors' nominal and actual efficiencies. Based on the difference between nominal and actual efficiency, energy loss is calculated for a particular motor. Conclusions about how energy savings depend on operating efficiency of induction motors are made and possible ways of increasing actual efficiency of induction motors provided