Show simple item record

dc.contributor.advisorHolm, J.E.W.
dc.contributor.advisorMoraal, H.
dc.contributor.authorStrachan, Stefanie
dc.date.accessioned2014-10-28T07:42:59Z
dc.date.available2014-10-28T07:42:59Z
dc.date.issued2013
dc.identifier.urihttp://hdl.handle.net/10394/12031
dc.descriptionMIng (Electrical and Electronic Engineering), North-West University, Potchefstroom Campus, 2014en_US
dc.description.abstractCosmic-ray fluctuations are monitored by neutron monitors using several different kinds of proportional counter tubes. An important component of these monitors is the electronic subsystem that registers and counts output pulses from these counter tubes. Part of the electronic subsystem is a specific preamplifier. The pulse-height distribution curve of the existing preamplifier used in the neutron monitor system at the Centre for Space Research at the North-West University was found to be incorrect, and therefore the pulse-height information cannot be used for further research on the counter tube characteristics. A correct pulse-height distribution implies that the envelope of the pulse, as generated by an amplifier, has a very specific shape as a result of the physics that governs the generation of pulses in the neutron counter tube. It was therefore proposed that a new charge-sensitive preamplifier be synthesized to provide an output that provides the correct pulse-height distribution graph for a neutron monitor system. The Centre for Space Research at the North-West University is in the process of designing and building a new mini neutron monitor system. The new charge-sensitive preamplifier will be implemented into this updated system. Ultimately, the electronic subsystem must be able to provide a pulse-height distribution graph at the push of a button, thus making the preamplifier a key component in the new design. In this dissertation the theory of charge-sensitive amplifiers is researched following a design science research methodology. The results showed that a charge-sensitive amplifier can be synthesized to address both the real-world requirements and the theoretical requirements of this research.en_US
dc.language.isoenen_US
dc.subjectNeutron monitoren_US
dc.subjectCharge-sensitive amplifieren_US
dc.subjectPreamplifieren_US
dc.subjectDesign science researchen_US
dc.subjectResearchen_US
dc.subjectDesignen_US
dc.subjectLadingsensitiewe versterkeren_US
dc.subjectVoorversterkeren_US
dc.subjectOntwerpwetenskapen_US
dc.subjectNavorsingen_US
dc.subjectOntwerpen_US
dc.titleSynthesis and evaluation of a charge sensitive amplifier for neutron countersen
dc.typeThesisen_US
dc.description.thesistypeMastersen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record